Test ID C3FX C3 Complement, Functional, Serum
Useful For
Diagnosis of C3 deficiency
Investigation of a patient with undetectable total complement (CH50) level
Method Name
Automated Liposome Lysis Assay
Reporting Name
C3 Complement, Functional, SSpecimen Type
Serum RedCollection Container/Tube: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions:
1. Immediately after drawing the specimen, place the tube on wet ice.
2. Spin down and separate serum from clot.
3. Immediately freeze specimen.
Additional Information: Fasting preferred.
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Serum Red | Frozen | 14 days |
Clinical Information
Complement proteins are components of the innate immune system. There are 3 pathways to complement activation: 1) the classic pathway, 2) the alternative (or properdin) pathway, and 3) the lectin activation (mannan-binding protein [MBP]) pathway. The classic pathway of the complement system is composed of a series of proteins that are activated in response to the presence of immune complexes. The activation process results in the generation of peptides that are chemotactic for neutrophils and that bind to immune complexes and complement receptors. The end result of the complement activation cascade is the formation of the lytic membrane attack complex (MAC).
The absence of early components (C1-C4) of the complement cascade results in the inability of immune complexes to activate the cascade. Patients with deficiencies of the early complement proteins are unable to clear immune complexes or to generate lytic activity. These patients have increased susceptibility to infections with encapsulated microorganisms. They may also have symptoms that suggest autoimmune disease and complement deficiency may be an etiologic factor in the development of autoimmune disease.
C3 is at the entry point for all 3 activation pathways to activate the MAC. C3 deficiency may result in pneumococcal and neisserial infections as well as autoimmune diseases such as glomerulonephritis.
Complement levels can be detected by antigen assays that quantitate the amount of the protein (C3 / Complement C3, Serum). For most of the complement proteins, a small number of cases have been described in which the protein is present but is non functional. These rare cases require a functional assay to detect the deficiency.
Reference Values
21-50 U/mL
Cautions
The total complement (CH50) assay (COM / Complement, Total, Serum) should be used as a screen for suspected complement deficiencies before ordering individual complement component assays. A deficiency of an individual component of the complement cascade will result in an undetectable total complement level.
Absent (or low) C3 functional levels in the presence of normal C3 antigen levels should be replicated with a new serum specimen to confirm that C3 inactivation did not occur during shipping.
Day(s) Performed
Monday through Saturday; Continuous with a 3 p.m. cutoff
Report Available
Same day/1 dayPerforming Laboratory

Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the U.S. Food and Drug Administration.CPT Code Information
86161