Test ID C4U C4 Acylcarnitine, Quantitative, Random, Urine


Ordering Guidance


This second-tier test is used specifically to evaluate a newborn screening elevation of iso-/butyrylcarnitine and must not be ordered with either C5OHU / C5-OH Acylcarnitine, Quantitative, Random, Urine or C5DCU / C5-DC Acylcarnitine, Quantitative, Random, Urine.

 

For general screening for metabolic disorders, see OAU / Organic Acids Screen, Random, Urine; ACRN / Acylcarnitines, Quantitative, Plasma; and AAQP / Amino Acids, Quantitative, Plasma.



Necessary Information


Include patient's age, family history, clinical condition (asymptomatic or acute episode), diet, and drug therapy information.

Specimen Required


Patient Preparation: If clinically feasible, discontinue L-carnitine supplementation at least 72 hours before specimen collection.

Supplies: Urine Tubes, 10 mL (T068)

Collection Container/Tube: Clean, plastic urine collection container

Submission Container/Tube: Plastic, 10 mL urine tube

Specimen Volume: 5 mL

Collection Instructions:

1. Collect a random urine specimen.

2. Freeze specimen immediately.


Secondary ID

88829

Useful For

Evaluation of patients with abnormal newborn screens showing elevations of iso-/butyrylcarnitine to aid in the differential diagnosis of short-chain acyl-CoA dehydrogenase and isobutyryl-CoA dehydrogenase deficiencies

Method Name

Flow Injection Analysis-Tandem Mass Spectrometry (FIA-MS/MS)

Reporting Name

C4 Acylcarnitine, QN, U

Specimen Type

Urine

Specimen Minimum Volume

1 mL

Specimen Stability Information

Specimen Type Temperature Time
Urine Frozen (preferred) 7 days
  Refrigerated  24 hours

Clinical Information

An isolated elevation of iso-/butyrylcarnitine (C4) in plasma or newborn screening blood spots is related to a diagnosis of either short chain acyl-CoA dehydrogenase (SCAD) deficiency or isobutyryl-CoA dehydrogenase (IBD) deficiency. Diagnostic testing by acylcarnitine analysis, including the evaluation of C4 excretion in urine, is necessary to differentiate the 2 clinical entities.(1) Patients with IBD deficiency excrete an abnormal amount of C4 acylcarnitine in urine, whereas patients with SCAD deficiency can have a normal excretion of this metabolite.

Reference Values

<3.00 millimoles/mole creatinine

Cautions

The results of urine acylcarnitines are typically not informative when the patient is receiving L-carnitine supplements.

Day(s) Performed

Monday, Wednesday, Friday

Report Available

2 to 5 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

82017

NY State Approved

Yes