Test ID C5FX C5 Complement, Functional, Serum
Useful For
Diagnosis of C5 deficiency
Investigation of a patient with an undetectable total complement (CH50) level
Method Name
Automated Liposome Lysis Assay
Reporting Name
C5 Complement, Functional, SSpecimen Type
Serum RedCollection Container/Tube: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions:
1. Immediately after drawing the specimen, place the tube on wet ice.
2. Spin down and separate serum from clot.
3. Immediately freeze specimen.
Additional Information: Fasting preferred.
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Serum Red | Frozen | 14 days |
Clinical Information
Complement proteins are components of the innate immune system. There are 3 pathways to complement activation: 1) the classic pathway, 2) the alternative (or properdin) pathway, and 3) the lectin activation (mannan-binding protein: MBP) pathway. The classic pathway of the complement system is composed of a series of proteins that are activated in response to the presence of immune complexes. The activation process results in the generation of peptides that are chemotactic for neutrophils and that bind to immune complexes and complement receptors. The end result of the complement activation cascade is the formation of the lytic membrane attack complex (MAC).
Patients with deficiencies of the late complement proteins (C5, C6, C7, C8, and C9) are unable to form the MAC and may have increased susceptibility to neisserial infections. More than 30 cases of C5 deficiency have been reported. Most of these patients have neisserial infections.
Complement levels can be detected by antigen assays that quantitate the amount of the protein (C5AG / C5 Complement, Antigen, Serum). For most of the complement proteins, a small number of cases have been described in which the protein is present but is nonfunctional. These rare cases require a functional assay to detect the deficiency.
Reference Values
29-53 U/mL
Cautions
The total complement (CH50) assay (COM / Complement, Total, Serum) should be used as a screen for suspected complement deficiencies before ordering individual complement component assays. A deficiency of an individual component of the complement cascade will result in an undetectable total complement level.
Absent (or low) C5 functional levels in the presence of normal C5 antigen levels should be replicated with a new serum specimen to confirm that C5 inactivation did not occur during shipping.
Day(s) Performed
Monday through Saturday; Continuous with a 3 p.m. cutoff
Report Available
Same day/1 dayPerforming Laboratory

Test Classification
This test has been modified from the manufacturer’s instructions. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
86161