Sign in →

Test ID CDA7X Drug Abuse Survey with Confirmation, Panel 9, Chain of Custody, Urine

Useful For

Detecting drug abuse involving alcohol, amphetamines, barbiturates, benzodiazepines, cocaine, methadone, opiates, phencyclidine, and tetrahydrocannabinol

                                

This chain-of-custody test is intended to be used in a setting where the test results can be used definitively to make a diagnosis.

Additional Tests

Test ID Reporting Name Available Separately Always Performed
COCH Chain of Custody Processing No Yes
ADLTX Adulterants Survey, CoC, U Yes Yes

Reflex Tests

Test ID Reporting Name Available Separately Always Performed
OPATX Opiate Confirmation, CoC, U Yes No
AMPHX Amphetamines Confirmation, CoC, U Yes No
BARBX Barbiturates Confirmation, CoC, U Yes No
BENZX Benzodiazepines Conf, CoC, U Yes No
COKEX Cocaine and metabolite Conf, CoC, U Yes No
ETOHX Ethanol, CoC, U Yes No
MTDNX Methadone Confirmation, CoC, U Yes No
PCPX Phencyclidine Confirmation, CoC, U Yes No
THCX Carboxy-THC Confirmation, CoC, U Yes No

Testing Algorithm

Testing begins with screening tests for alcohol and drugs of abuse. Positives are confirmed and quantitated by definitive methods (gas chromatography-flame ionization detector for ethanol; gas chromatography-mass spectrometry for barbiturates, benzodiazepines, cocaine and metabolites, methadone, phencyclidine, and tetrahydrocannabinol metabolite) at an additional charge. Amphetamines and opiates that screen positive will be quantified with liquid chromatography-tandem mass spectrometry (LC-MS/MS) at an additional charge.

 

Adulterants testing will be performed on all chain-of-custody urine samples as per regulatory requirements.

Method Name

CDA7X: Alcohol Screened by an Enzymatic Assay/All Others Screened by Immunoassay
ETOHX: Ethanol Confirmed by Gas Chromatography-Flame Ionization Detector (GC-FID)

Reporting Name

Confirmed Drug Abuse Panel9, CoC, U

Specimen Type

Urine

Container/Tube: Chain-of-Custody Kit (T282) containing the specimen containers, seals, and documentation required

Specimen Volume: 30 mL      

Collection Instructions: Collect specimen in the provided container, seal, and submit with the associated documentation to satisfy the legal requirements for chain-of-custody testing.

Additional Information: Submitting less than 30 mL will compromise our ability to perform all necessary testing.

Forms: Chain-of-Custody Request Form is included in the Chain-of-Custody Kit (T282). A copy of this form is also available at http://www.mayomedicallaboratories.com/it-mmfiles/chain-of-custody-request-form.pdf.

Specimen Minimum Volume

15 mL

Specimen Stability Information

Specimen Type Temperature Time
Urine Refrigerated (preferred) 14 days
  Frozen  14 days
  Ambient  72 hours

Clinical Information

This assay was designed to test for and confirm by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-tandem mass spectrometry (LC-MS/MS) the most common classes of drugs of abuse.

                     

This test uses the simple screening technique which involves immunologic testing for drugs by class. All positive screening results are confirmed by GC-MS (positive alcohol by GC) or LC-MS/MS and quantitated, before a positive result is reported.

 

Chain of custody is a record of the disposition of a specimen to document who collected it, who handled it, and who performed the analysis. When a specimen is submitted in this manner, analysis will be performed in such a way that it will withstand regular court scrutiny. Chain of custody is required whenever the results of testing could be used in a court of law. Its purpose is to protect the rights of the individual contributing the specimen by demonstrating that it was under the control of personnel involved with testing the specimen at all times; this control implies that the opportunity for specimen tampering would be limited.

Reference Values

Negative

Screening cutoff concentrations

Amphetamines: 500 ng/mL

Barbiturates: 200 ng/mL

Benzodiazepines: 100 ng/mL

Cocaine (benzoylecgonine-cocaine metabolite): 150 ng/mL

Ethanol: 10 mg/dL

Methadone metabolite: 300 ng/mL

Opiates: 300 ng/mL

Phencyclidine: 25 ng/mL

Tetrahydrocannabinol carboxylic acid: 50 ng/mL

This report is intended for use in clinical monitoring or management of patients. It is not intended for use in employment-related testing.

Cautions

Not intended for use in employment-related testing.

                                

The test does not screen for drug classes other than those listed above. More comprehensive screening is available using the serum or urine drug screens (DSSX / Drug Screen, Prescription/OTC, Chain of Custody, Serum or PDSUX / Drug Screen, Prescription/OTC, Chain of Custody, Urine).

Day(s) Performed

Monday through Friday

Report Available

Same day/1 day

Performing Laboratory

Mayo Medical Laboratories in Rochester

Test Classification

This test has been cleared or approved by the U.S. Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

80301

G0479 (if appropriate)

NY State Approved

No