Test ID CSMEU Controlled Substance Monitoring Enhanced Profile with Reflex, 21 Drug Classes, High Resolution Mass Spectrometry and Immunoassay Screen, Random, Urine
Ordering Guidance
This test does not screen for drug classes other than those listed above.
Specimen Required
Supplies: Urine Container, 60 mL (T313)
Collection Container/Tube: Plastic urine container
Submission Container/Tube: Plastic, 60 mL urine container
Specimen Volume: 30 mL
Collection Instructions:
1. Collect a random urine specimen.
2. Submit 30 mL in 1 plastic bottle.
3. No preservative.
Additional Information:
1. No specimen substitutions.
2. Submitting less than 30 mL may compromise the ability to perform all necessary testing.
3. STAT requests are not accepted for this procedure.
Forms
If not ordering electronically, complete, print, and send a Therapeutics Test Request (T831) with the specimen.
Secondary ID
615907Useful For
Detecting drug use involving stimulants, barbiturate, benzodiazepines, cocaine, opioids, tetrahydrocannabinol, and alcohol
This test is not intended for use in employment-related testing.
Profile Information
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
LPCM | List Patient's Current Medications | No | Yes |
ADULT | Adulterants Survey, U | Yes | Yes |
PNRCH | Drug Immunoassay Panel, U | No | Yes |
TOPSU | Targeted Opioid Screen, U | Yes, (Order TOSU) | Yes |
TABSU | Targeted Benzodiazepine Screen, U | Yes, (Order TBSU) | Yes |
TSTIM | Targeted Stimulant Screen, U | Yes, (Order TSPU) | Yes |
ETGSR | Ethyl Glucuronide Scrn w/Reflex, U | No | Yes |
Reflex Tests
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
COKEU | Cocaine and metabolite Conf, U | Yes | No |
BARBU | Barbiturates Confirmation, U | Yes | No |
THCU | Carboxy-THC Confirmation, U | Yes | No |
ETGC | Ethyl Glucuronide Confirmation, U | Yes | No |
Testing Algorithm
Testing begins with an adulterant survey. If the sample is found to be adulterated, testing will end, and the remaining tests will be canceled.
If the specimen is normal or only diluted, remaining testing will continue.
If immunoassay screen is positive, confirmation testing can be ordered separately. Confirmation with quantification of positives for barbiturates, cocaine and metabolites, tetrahydrocannabinol metabolite, and ethyl glucuronide/ethyl sulfate will be performed at an additional charge.
Method Name
ADULT: Spectrophotometry (SP)
PNRCH: Screened by Immunoassay/Confirmed by Gas Chromatography-Mass Spectrometry (GC-MS)
TOPSU, TABSU, TSTIM: Liquid Chromatography-Tandem Mass Spectrometry, High-Resolution Accurate Mass (LC-MS/MS HRAM)
ETGSR: Screened by Immunoassay/Confirmed by Liquid Chromatography-Tandem Mass Spectrometry
Reporting Name
CSM Enhanced Profile,21, HRMS/IA, USpecimen Type
UrineSpecimen Minimum Volume
20 mL
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Urine | Refrigerated (preferred) | 14 days |
Frozen | 14 days |
Clinical Information
This test uses screening techniques that involves immunologic testing and high-resolution accurate mass spectrometry screening for drugs by class. All positive immunoassay screening results are confirmed by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-tandem mass spectrometry (LC-MS/MS), and quantitated, before a positive result is reported.
The following drugs/drug classes are tested by immunoassay and confirmed by GC-MS:
-Barbiturates
-Cocaine
-Tetrahydrocannabinol
Ethyl glucuronide is also screened using an immunoassay and confirmation of ethyl glucuronide/ethyl sulfate is performed using LC-MS/MS.
The targeted opioid, benzodiazepine, and stimulant screen portions are performed using liquid chromatography-tandem mass spectrometry, high-resolution accurate mass (HRAM) and are completed for all opioids, benzodiazepines, and stimulants. Opioids are a large class of medications commonly used to relieve acute and chronic pain or help manage opioid abuse and dependence. Medications that fall into this class include buprenorphine, codeine, fentanyl, hydrocodone, hydromorphone, methadone, morphine, oxycodone, oxymorphone, tapentadol, tramadol, and others. Opioids work by binding to the opioid receptors that are found in the brain, spinal cord, gastrointestinal tract, and other organs. Common side effects include drowsiness, confusion, nausea, constipation, and, in severe cases, respiratory depression depending on the dose. These medications can also produce physical and psychological dependence and have a high risk for abuse and diversion, which is one of the main reasons many professional practice guidelines recommend compliance testing in patients prescribed these medications.
Opioids are readily absorbed from the gastrointestinal tract, nasal mucosa, lungs, and after subcutaneous or intermuscular injection. Opioids are primarily excreted from the kidney in both free and conjugated forms. This assay doesn't hydrolyze the urine sample and looks for both parent drugs and metabolites (including glucuronide forms). The detection window for most opioids in urine is approximately 1 to 3 days with longer detection times for some compounds (ie, methadone).
Benzodiazepines represent a large family of medications used to treat a wide range of disorders from anxiety to seizures and are also used in pain management. With a high risk for abuse and diversion, professional practice guidelines recommend compliance monitoring for these medications using urine drug tests. However, traditional benzodiazepine immunoassays suffer from a lack of cross-reactivity with all the benzodiazepines, so many compliant patients taking clonazepam (Klonopin) or lorazepam (Ativan) may screen negative by immunoassay but are positive when confirmatory testing is done. The new targeted benzodiazepine screening test provides a more sensitive and specific test to check for compliance to all the commonly prescribed benzodiazepines and looks for both parent and metabolites in the urine.
Stimulants are sympathomimetic amines that stimulate the central nervous system activity and, in part, suppress the appetite. Amphetamine and methamphetamine are also prescription drugs used in the treatment of narcolepsy and attention-deficit disorder/attention-deficit hyperactivity disorder (ADHD). Methylphenidate is another stimulant used to treat ADHD. Phentermine is indicated for the management of obesity. All of the other amphetamines (eg, methylenedioxymethamphetamine: MDMA) are Drug Enforcement Administration scheduled Class I compounds. Due to their stimulant effects, the drugs are commonly sold illicitly and abused. Physiological symptoms associated with very high amounts of ingested amphetamine or methamphetamine include elevated blood pressure, dilated pupils, hyperthermia, convulsions, and acute amphetamine psychosis.
Ethyl glucuronide is a direct metabolite of ethanol that is formed by enzymatic conjugation of ethanol with glucuronic acid. Alcohol in urine is normally detected for only a few hours, whereas ethyl glucuronide can be detected in the urine for 1 to 5 days. This procedure uses immunoassay reagents that are designed to produce a negative result when no drugs are present in a natural (eg, unadulterated) specimen of urine; the assay is designed to have a high true-negative rate. Like all immunoassays, it can have a false-positive rate due to cross-reactivity with natural chemicals and drugs other than those they were designed to detect. The immunoassay also has a false-negative rate to the antibody's ability to cross-react with different drugs in the class being screened for.
This test is intended to be used in a setting where the test results can be used to make a definitive diagnosis
Reference Values
ADULTERANT SURVEY:
Cutoff concentrations
Oxidants: 200 mg/L
Nitrites: 500 mg/L
DRUG IMMUNOASSAY PANEL:
Negative
Screening cutoff concentrations:
Barbiturates: 200 ng/mL
Cocaine (benzoylecgonine-cocaine metabolite): 150 ng/mL
Tetrahydrocannabinol carboxylic acid: 50 ng/mL
This report is intended for use in clinical monitoring or management of patients. It is not intended for use in employment-related testing.
TARGETED OPIOID SCREEN:
Not Detected
Cutoff concentrations:
Codeine: 25 ng/mL
Codeine-6-beta-glucuronide: 100 ng/mL
Morphine: 25 ng/mL
Morphine-6-beta-glucuronide: 100 ng/mL
6-monoacetylmorphine: 25 ng/mL
Hydrocodone: 25 ng/mL
Norhydrocodone: 25 ng/mL
Dihydrocodeine: 25 ng/mL
Hydromorphone: 25 ng/mL
Hydromorphone-3-beta-glucuronide: 100 ng/mL
Oxycodone: 25 ng/mL
Noroxycodone: 25 ng/mL
Oxymorphone: 25 ng/mL
Oxymorphone-3-beta-glucuronide: 100 ng/mL
Noroxymorphone: 25 ng/mL
Fentanyl: 2 ng/mL
Norfentanyl: 2 ng/mL
Meperidine: 25 ng/mL
Normeperidine: 25 ng/mL
Naloxone: 25 ng/mL
Naloxone-3-beta-glucuronide: 100 ng/mL
Methadone: 25 ng/mL
EDDP: 25 ng/mL
Propoxyphene: 25 ng/mL
Norpropoxyphene: 25 ng/mL
Tramadol: 25 ng/mL
O-desmethyltramadol: 25 ng/mL
Tapentadol: 25 ng/mL
N-desmethyltapentadol: 50 ng/mL
Tapentadol-beta-glucuronide: 100 ng/mL
Buprenorphine: 5 ng/mL
Norbuprenorphine: 5 ng/mL
Norbuprenorphine glucuronide: 20 ng/mL
TARGETED BENZODIAZEPINE SCREEN:
Not Detected
Cutoff concentrations:
Alprazolam: 10 ng/mL
Alpha-Hydroxyalprazolam: 10 ng/mL
Alpha-Hydroxyalprazolam Glucuronide: 50 ng/mL
Chlordiazepoxide: 10 ng/mL
Clobazam: 10 ng/mL
N-Desmethylclobazam: 200 ng/mL
Clonazepam: 10 ng/mL
7-aminoclonazepam: 10 ng/mL
Diazepam: 10 ng/mL
Nordiazepam: 10 ng/mL
Flunitrazepam: 10 ng/mL
7-aminoflunitrazepam: 10 ng/mL
Flurazepam: 10 ng/mL
2-Hydroxy Ethyl Flurazepam: 10 ng/mL
Lorazepam: 10 ng/mL
Lorazepam Glucuronide: 50 ng/mL
Midazolam: 10 ng/mL
Alpha-Hydroxy Midazolam: 10 ng/mL
Oxazepam: 10 ng/mL
Oxazepam Glucuronide: 50 ng/mL
Prazepam: 10 ng/mL
Temazepam: 10 ng/mL
Temazepam Glucuronide: 50 ng/mL
Triazolam: 10 ng/mL
Alpha-Hydroxy Triazolam: 10 ng/mL
Zolpidem: 10 ng/mL
Zolpidem Phenyl-4-Carboxylic acid: 10 ng/mL
TARGETED STIMULANT SCREEN:
Not Detected
Cutoff concentrations:
Methamphetamine: 100 ng/mL
Amphetamine: 100 ng/mL
3,4-methylenedioxymethamphetamine (MDMA): 100 ng/mL
3,4-methylenedioxy-N-ethylamphetamine (MDEA): 100 ng/mL
3,4-methylenedioxyamphetamine (MDA): 100 ng/mL
Ephedrine: 100 ng/mL
Pseudoephedrine: 100 ng/mL
Phentermine: 100 ng/mL
Phencyclidine (PCP): 20 ng/mL
Methylphenidate: 20 ng/mL
Ritalinic acid: 100 ng/mL
ETHYL GLUCURONIDE SCREEN:
Negative
Screening cutoff concentrations:
Ethyl Glucuronide: 500 ng/mL
Cautions
In regards to ethyl glucuronide testing, care should be taken when interpreting results since there are many factors (eg, fluid intake and other biologic factors) that may influence a urine test result. It is possible that substances other than those investigated in the specificity study may interfere with the test and cause false-positive or false-negative results.
Day(s) Performed
Monday through Saturday
Report Available
3 to 4 daysPerforming Laboratory

Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
80307
80347
80364
80326
G0482 (if appropriate)