Sign in →

Test ID DIPGS Diphtheria Toxoid IgG Antibody, Serum

Useful For

Determining a patient’s immunological response to diphtheria toxoid vaccination

 

An aid in the evaluation of immunodeficiency

Method Name

Enzyme Immunoassay (EIA)

Reporting Name

Diphtheria Toxoid IgG Ab, S

Specimen Type

Serum

Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Specimen Volume: 0.5 mL

Specimen Minimum Volume

0.4 mL

Specimen Stability Information

Specimen Type Temperature Time
Serum Refrigerated (preferred) 30 days
  Frozen  30 days

Clinical Information

Diphtheria is an acute, contagious, febrile illness caused by the bacterium Corynebacterium diphtheriae. The disease is classically characterized by a combination of localized inflammation in the upper respiratory tract with the formation of a diphtheric pseudomembrane over the oropharynx, including the tonsils, pharynx, larynx and posterior nasal passages. Corynebacterium diphtheriae produces a potent diphtheria exotoxin which is absorbed systemically and can lead to cardiac failure and paralysis of the diaphragm.

 

The disease is preventable by vaccination with diphtheria toxoid, which stimulates anti-diphtheria toxoid antibodies. In the United States, diphtheria toxoid is administered to children as part of the combined diphtheria, tetanus, and acellular pertussis (TDaP) vaccine. A patient’s immunological response to diphtheria toxoid vaccination can be determined by measuring anti-diphtheria toxoid IgG antibody using this enzyme immunoassay technique. An absence of antibody formation post-vaccination may relate to immune deficiency disorders, either congenital or acquired, or iatrogenic due to immunosuppressive drugs.

Reference Values

Vaccinated: Positive (≥0.01 IU/mL)

Unvaccinated: Negative (<0.01 IU/mL)

Cautions

This assay does not provide diagnostic proof of lack of protection against diphtheria or the presence of absence of immunodeficiency. Results must be confirmed by clinical findings and other serological tests.

Day(s) Performed

Monday through Friday; 9 a.m.

Report Available

Same day/1 day

Performing Laboratory

Mayo Medical Laboratories in Rochester

Test Classification

This test has been cleared or approved by the U.S. Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

86317

NY State Approved

Yes