Test ID DXPIN Doxepin and Nordoxepin, Serum
Specimen Required
Collection Container/Tube: Red top (Serum gel/SST are not acceptable)
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions:
1. Collect specimen immediately before next scheduled dose (minimum 12 hours after last dose).
2. Centrifuge and aliquot serum into plastic vial. Serum must be separated from cells within 2 hours of collection.
Forms
If not ordering electronically, complete, print, and send a Therapeutics Test Request (T831) with the specimen.
Useful For
Monitoring doxepin therapy
Evaluating potential doxepin toxicity
Evaluating patient compliance
Method Name
Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS)
Reporting Name
Doxepin and Nordoxepin, SSpecimen Type
Serum RedSpecimen Minimum Volume
0.25 mL
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Serum Red | Refrigerated (preferred) | 28 days |
Frozen | 28 days | |
Ambient | 7 days |
Clinical Information
Doxepin is recommended for the treatment of psychoneurotic patients with depression or anxiety, or with depression or anxiety associated with alcoholism or organic disease.
Nordoxepin (N-desmethyldoxepin) is the major metabolite and is usually present at concentrations equal to doxepin. Optimal efficacy occurs at combined serum concentrations between 50 and 150 ng/mL.
Like other tricyclic antidepressants, the major toxicity of doxepin is expressed as cardiac dysrhythmias, which occur at concentrations in excess of 500 ng/mL. Other side effects include nausea, hypotension, and dry mouth.
Reference Values
Therapeutic concentration (doxepin + nordoxepin): 50-150 ng/mL
Note: Therapeutic ranges are for specimens drawn at trough (ie, immediately before next scheduled dose). Levels may be elevated in non-trough specimens.
Cautions
This test cannot be performed on whole blood. Serum must be separated from cells within 2 hours of collection; if serum is not removed within this time, tricyclic antidepressant levels may be falsely elevated due to drug release from red blood cells.
Specimens that are obtained from gel tubes are not acceptable because the drug can absorb on the gel and lead to falsely decreased concentrations.
Day(s) Performed
Tuesday, Thursday, Sunday
Report Available
3 to 5 daysPerforming Laboratory

Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
80335
G0480 (if appropriate)