Test ID ETX Ethosuximide, Serum
Method Name
Enzyme-Multiplied Immunoassay Technique (EMIT)
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 0.5 mL
Collection Instructions:
1. Serum gel tubes should be centrifuged within 2 hours of collection.
2. Red-top tubes should be centrifuged and the serum aliquoted into a plastic vial within 2 hours of collection.
Reporting Name
Ethosuximide, SSpecimen Type
SerumSpecimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Serum | Refrigerated (preferred) | 14 days |
| Frozen | 28 days | |
| Ambient | 14 days |
Report Available
Same day/1 dayPerforming Laboratory
Mayo Clinic Laboratories in Rochester
LOINC Code Information
| Test ID | Test Order Name | Order LOINC Value |
|---|---|---|
| ETX | Ethosuximide, S | 3616-0 |
| Result ID | Test Result Name | Result LOINC Value |
|---|---|---|
| 8769 | Ethosuximide, S | 3616-0 |
Forms
If not ordering electronically, complete, print, and send 1 of the following forms with the specimen:
-Therapeutics Test Request (T831)
Useful For
Monitoring ethosuximide therapy
Determining compliance
Assessing ethosuximide toxicity
Day(s) Performed
Monday through Saturday
Test Classification
This test has been modified from the manufacturer's instructions. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
80168
Specimen Minimum Volume
0.25 mL
Reference Values
Therapeutic: 40-100 mcg/mL
Critical value: >150 mcg/mL