Sign in →

Test ID FADDP Adenosine Deaminase, Pericardial Fluid


Specimen Required


Specimen Type: Pericardial Fluid

Sources: Pericardial Fluid

Container/Tube: Standard Transport Tube

Specimen Volume: 0.5 mL

Collection Instructions: Collect Pericardial Fluid in a leak-proof container. Centrifuge specimen at room temperature, transfer 0.5 mL pericardial fluid to plastic vial and freeze.

 

Note: Specimen must remain frozen until received at performing lab.


Secondary ID

75667

Method Name

Quantitative Spectrophotometry

Reporting Name

Adenosine Deaminase Pericardial Fld

Specimen Type

Body Fluid

Specimen Minimum Volume

0.2 mL

Specimen Stability Information

Specimen Type Temperature Time
Body Fluid Frozen (preferred) 30 days
  Refrigerated  7 days

Reference Values

0-40 U/L

Day(s) Performed

Sunday, Tuesday, Thursday

Report Available

1 to 8 days

Performing Laboratory

ARUP Laboratories

Test Classification

This test was developed and its performance characteristics determined by ARUP Laboratories. It has not been cleared or approved by the US Food and Drug Administration. This test was performed in a CLIA certified laboratory and is intended for clinical purposes.

CPT Code Information

84311

NY State Approved

Yes