Test ID FC4A C4ades Arg Level
Reporting Name
C4a LevelSpecimen Type
Plasma EDTADraw blood in a lavender-top (EDTA) tube(s), plasma gel tube(s) is not acceptable. Mix well, centrifuge at ambient temperature within one half hour of draw (preferably immediately after venipuncture), and freeze immediately on dry ice or at -70 C. Send 1 mL of EDTA plasma frozen in plastic vial.
Complete and submit with specimen:
1. National Jewish Complement request form
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Plasma EDTA | Frozen | 365 days |
Reference Values
0 – 2830 ng/mL
Day(s) Performed
1st and 3rd Thursday of month
Report Available
21 daysPerforming Laboratory
National Jewish HealthTest Classification
This test uses a kit/reagent designated by the manufacturer as for research use, not for clinical use. The performance characteristics for this test have been validated by Advanced Diagnostics Laboratories at National Jewish Health. It has not been cleared or approved by the US Food and Drug Administration. The results are not intended to be used as the sole means for clinical diagnosis or patient management decisions. This laboratory is certified under the Clinical Laboratory Improvement Amendments of 1988 (CLIA-88) as qualified to perform high complexity clinical laboratory testing.CPT Code Information
86160