Sign in →

Test ID FDS9R Drug Screen 9 Panel, Serum or Plasma-Immunoassay Screen with Reflex to Mass Spectrometry Confirmation/Quantitation

Reflex Tests

Test ID Reporting Name Available Separately Always Performed
FCOCF Cocaine Met, S/P, Quant No No
FMMSP Methadone and Met, S/P, Quant No No
FBCON Barbiturates, Confirmation No No
FOPIA Opiates, Serum or Plasma, Quant. Yes No
FAMCO Amphetamine, S/P, Quant No No
FPROC Propoxyphene and Met, S/P, Quant No No
FMETQ THC Metabolite, S/P, Quant No No
FBENQ Benzodiazepines, S/P, Quant No No
FDS93 Phencyclidine (PCP), S/P, Quant No No

Testing Algorithm

If screen is positive, specimens are automatically confirmed by GC/MS and/or LC/MS/MS at an additional charge.

Method Name

Qualitative Enzyme-Linked Immunosorbent Assay

Quantitative Gas Chromatography-Mass Spectrometry

Quantitative Liquid Chromatography-Tandem Mass Spectrometry

Reporting Name

Drug Screen 9 Pnl, with Reflex

Specimen Type

Varies

Submit only one of the following:

 

Plasma

Draw blood in a gray top potassium oxalate/sodium fluoride, green (sodium heparin), lavender (EDTA), or pink (K2EDTA) tube(s). Spin down and send 4 mL of plasma refrigerate in a plastic vial.

 

Serum

Draw blood in a plain, red-top tube(s). Spin down and send 4 mL of serum refrigerate in a plastic vial.

 

Note: Cocaine and cocaethylene are more stable in fluoride-preserved plasma than serum.

Specimen Minimum Volume

3 mL

Specimen Stability Information

Specimen Type Temperature Time
Varies Refrigerated (preferred) 14 days
  Ambient  7 days
  Frozen 

Reference Values

         Drugs Covered and Cutoff Concentrations:

Drugs/Drug Classes

Screen Cutoff

Amphetamines

30 ng/mL

Methamphetamine

30 ng/mL

Barbiturates

75 ng/mL

Benzodiazepines

75 ng/mL

Cannabinoids

30 ng/mL

Cocaine

30 ng/mL

Methadone

40 ng/mL

Opiates

30 ng/mL

Oxycodone

30 ng/mL

Phencyclidine

15 ng/mL

Propoxyphene

75 ng/mL

 

Drugs/Drug classes reported as "Positive" are automatically reflexed to mass spectrometry confirmation/quantitation testing.  An immunoassay unconfirmed positive screen result may be useful for medical purposes but does not meet forensic standards.

 

For medical purposes only; not valid for forensic use.

 

Day(s) Performed

Sunday through Saturday

Report Available

1 - 4 days

Performing Laboratory

ARUP Laboratories

Test Classification

This test was developed and its performance characteristics determined by ARUP Laboratories. The U.S. Food and Drug Administration has not approved or cleared this test; however, FDA clearance or approval is not currently required for clinical use. The results are not intended to be used as the sole means for clinical diagnosis or patient management decisions.

CPT Code Information

80301

80349-Cannabinoids (if appropriate)

80353-Cocaine (if appropriate)

80361/80365-Opiates (if appropriate)

83992-Phencyclidine (if appropriate)

80324/80359-Amphetamines (if appropriate)

80345-Barbiturates (if appropriate)

80347-Benzodiazepines (if appropriate)

80358-Methadone & Metabolite (if appropriate)

80367-Propoxyphene (if appropriate)

NY State Approved

Yes