Test ID FLALA Limulus Amebocyte Lysate (Endotoxin)
Profile Information
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
FLAL | Limulus Lysate Assay | No | Yes |
FLAL2 | Limulus Lysate | No | No |
FLAL3 | Limulus Lysate | No | No |
FLAL4 | Limulus Lysate | No | No |
Testing Algorithm
If additional specimen dilutions are required to obtain an accurate result, up to 3 additional dilutions could be performed, each at an additional charge.
Method Name
Kinetic
Reporting Name
Limulus Amebocyte Lysate, EndotoxinSpecimen Type
Varies5 mL aqueous solution used in patient management. Send solution frozen in non-pyrogenic, plastic container.
NOTE: 1. Submit name of aqueous solution, and the diluent if applicable.
2. Body fluids are not acceptable.
3. Glass vials are not acceptable.
Specimen Minimum Volume
3 mL
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Varies | Frozen | 30 days |
Reference Values
LEVEL DETECTED INTERPRETATION
<0.05 EU/mL None Detected
0.125 EU/mL Action level for dialysis water
<0.25 EU/mL Maximum allowable level for dialysis water and USP acceptable limits for injectable or irrigation water
0.25 EU/mL Action level for dialysis fluid
<0.50 EU/mL Maximum allowable level for dialysis fluid and USP acceptable limits for inhalatory water.
2.00 EU/mL Acceptable upper limit for Hemodialysis reuse water.
The LAL is used as a quantitative test to detect gram-negative endotoxin in aqueous solutions used in patient management. The LAL assay is not recommended for serum or plasma samples due to the presence of inhibitory factors. It is essential to maintain specimen sterility and prevent false positive results from exogenous gram negative bacteria.
Day(s) Performed
Monday through Friday
Report Available
1 - 4 daysPerforming Laboratory
Focus Diagnositics, Inc.CPT Code Information
No CPT code available on Non-Biological specimens