Test ID FLEC Flecainide, Serum

Useful For

Optimizing dosage

 

Assessing toxicity

 

Monitoring compliance

Method Name

High-Performance Liquid Chromatography (HPLC)

Reporting Name

Flecainide, S

Specimen Type

Serum Red

Sample must be centrifuged and serum aliquoted off within 2 hours of draw.

 

Container/Tube: Red top

Specimen Volume: 3 mL

Specimen Minimum Volume

1.1 mL

Specimen Stability Information

Specimen Type Temperature Time
Serum Red Refrigerated (preferred) 28 days
  Ambient  28 days
  Frozen  28 days

Clinical Information

Flecainide (Tambocor) is a class I cardiac antiarrhythmic agent with electrophysiologic properties similar to lidocaine, quinidine, procainamide, and tocainide. Flecainide produces a dose-related decrease in intracardiac conduction in all parts of the heart, with the greatest effect on the His-Purkinje system. Atrial effects are limited. Flecainide causes a dose-related and plasma concentration-related decrease in single and multiple premature ventricular contractions and can suppress recurrence of ventricular tachycardia.

 

Flecainide is eliminated from blood by hepatic metabolism as well as renal clearance; significant changes in either organ system will cause impaired clearance. During preclinical trials, patients with congestive heart failure were observed to have radically altered clearance properties. Cardiac toxicity attributed to flecainide is related to its cardiac conduction slowing properties. Excessive prolongation of PR, QRS, and QT intervals occurs with increased amplitude of the T wave. Reductions in myocardial rate, contractility, as well as conduction disturbances, are also associated with excessive dose and plasma concentration of flecainide.

 

Death can occur from hypotension, respiratory failure, and asystole.

 

Flecainide is contraindicated in patients with sick sinus syndrome. It causes sinus bradycardia, sinus pause, or sinus arrest.

Reference Values

0.2-1.0 mcg/mL

Cautions

No significant cautionary statements

Day(s) Performed

Monday, Wednesday, Friday; 9:00 a.m.

Report Available

Same day/1 day

Performing Laboratory

Mayo Medical Laboratories in Rochester

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the U.S. Food and Drug Administration.

CPT Code Information

80299

NY State Approved

Yes