Test ID FLUOX Fluoxetine, Serum
Useful For
Monitoring serum concentration of fluoxetine during therapy
Evaluating potential toxicity
Evaluating patient compliance
Method Name
High-Turbulence Liquid Chromatography Mass Spectrometry (HTLC-MS/MS)
Reporting Name
Fluoxetine, SSpecimen Type
Serum RedContainer/Tube: Red top
Specimen Volume: 1 mL
Collection Instructions: Spin down and separate serum from cells within 2 hours of draw.
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Serum Red | Refrigerated (preferred) | 14 days |
Frozen | 14 days | |
Ambient | 24 hours |
Clinical Information
Fluoxetine is a selective serotonin reuptake inhibitor approved for treatment of bulimia, obsessive-compulsive behavior, panic, premenstrual dysphoria, and major depressive disorder, with a variety of off-label uses. Both fluoxetine and its major metabolite, norfluoxetine, are pharmacologically active, and are reported together in this assay. Most individuals respond optimally when combined serum concentrations for both parent and metabolite are in the therapeutic range (120-300 ng/mL) at steady state. Due to the long half-lives of parent and metabolite (1-6 days), it may take several weeks for patients to reach steady-state concentrations. Fluoxetine is a potent inhibitor of the metabolic enzyme CYP2D6, with lesser inhibitory effects on CYP2C19 and CYP3A. Therapy with fluoxetine is therefore subject to numerous drug interactions, which is compounded by wide interindividual variability in fluoxetine pharmacokinetics. Measurement of the drug is useful for managing comedications, dose or formulation changes, and in assessing compliance. Side effects are milder for fluoxetine than for older antidepressants such as the tricyclics. The most common side effects of fluoxetine therapy include nausea, nervousness, anxiety, insomnia, and drowsiness. Anticholinergic and cardiovascular side effects are markedly reduced compared to tricyclic antidepressants. Fatalities from fluoxetine overdose are extremely rare.
Reference Values
Fluoxetine + norfluoxetine: 120-300 ng/mL
Cautions
This test cannot be performed on whole blood. Serum must be separated from cells within 2 hours of draw. Specimens that are obtained from gel tubes are not acceptable.
Day(s) Performed
Wednesday; 12 a.m.
Report Available
1 day/2 daysPerforming Laboratory

Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the U.S. Food and Drug Administration.CPT Code Information
80299