Test ID FSUCC Succinyladenosine, CSF
Method Name
High Performance Liquid Chromatography-Electrochemistry
Reporting Name
Succinyladenosine, CSFSpecimen Type
CSFSubmit 1 mL of spinal fluid (CSF) in a sterile, plastic screw-cap vial. Freeze specimen after collection and ship at frozen temperature.
Note: Complete and submit with specimen, Medical Neurogenetics Neurochemistry request form with Physician name and phone number. Also include test required, sample date, date of birth, current medications and relevant history.
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
CSF | Frozen |
Reference Values
Reference Range: 0.74 – 4.92 umol/L
Day(s) Performed
Monday through Friday
Report Available
14 daysPerforming Laboratory
Medical Neurogenetics, LLCTest Classification
This test was developed and its performance characteristics determined by Medical Neurogenetics, LCC. It has not been cleared or approved by the U.S. FDA.CPT Code Information
82542