Test ID GAL3 Galectin-3, Serum
Useful For
An aid in prognosis for patients diagnosed with heart failure
Risk-stratification of heart failure patients
An early indication of treatment failure and as a therapeutic target
Method Name
Enzyme-Linked Immunosorbent Assay (ELISA)
Reporting Name
Galectin-3, SSpecimen Type
Serum RedCollection Container/Tube: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Forms: If not ordering electronically, complete, print, and send a Cardiovascular Test Request Form (T724) with the specimen (http://www.mayomedicallaboratories.com/media/customer-service/forms/cardiovascular-request-form.pdf).
Specimen Minimum Volume
0.2 mL
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Serum Red | Frozen (preferred) | 365 days |
Refrigerated | 24 hours |
Clinical Information
Heart failure is a complex cardiovascular disorder with a variety of etiologies and heterogeneity with respect to the clinical presentation of the patient. Heart failure is significantly increasing in prevalence with an aging population and is associated with high short- and long-term mortality rate. Over 80% of patients diagnosed and treated for acute heart failure syndromes in the emergency department are readmitted within the forthcoming year, incurring costly treatments and therapies.(1)
The development and progression of heart failure is a clinically silent process until manifestation of the disorder, which typically occurs late and irreversibly into its progression. Mechanistically, heart failure, whether due to systolic or diastolic dysfunction, is thought to progress primarily through adverse cardiac remodeling and fibrosis in response to cardiac injury and/or stress. Galectin-3 is a biomarker that appears to be actively involved in both the inflammatory and fibrotic pathways that are thought to be involved.
Galectin-3 is a carbohydrate-binding lectin whose expression is associated with inflammatory cells including macrophages, neutrophils, and mast cells. Galectin-3 has been linked to cardiovascular physiological processes including myofibroblast proliferation, tissue repair, and cardiac remodeling in the setting of heart failure. Concentrations of galectin-3 have been used to predict adverse remodeling after a variety of cardiac insults.
Reference Values
<24 months: not established
2-17 years: ≤25.0 ng/mL
≥18 years: ≤22.1 ng/mL
Cautions
Hemolysis has been shown to interfere with the galectin-3 assay due to intracellular release of galectin-3. Specimens that are visibly hemolyzed will be rejected.
Heterophile antibodies, in particular human-antimouse antibodies in human serum, may cause falsely elevated galectin-3 results. Heterophile antibodies may react with reagent immunoglobulins and subsequently interfere with in vitro immunoassays. Patients routinely exposed to animals or to animal serum products can be prone to this interference and anomalous high or low values can be observed.
Patients with high concentrations of rheumatoid factor, as well as other autoimmune disorders, may also yield falsely elevated results and should be interpreted with caution.
Day(s) Performed
Monday; 9 a.m.
Report Available
1 dayPerforming Laboratory

Test Classification
This test has been cleared or approved by the U.S. Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information