Sign in →

Test ID GAL3 Galectin-3, Serum


Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube: Red top (serum gel/SST are not acceptable)

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL

Collection Instructions: Centrifuge and aliquot serum into plastic vial.


Forms

If not ordering electronically, complete, print, and send a Cardiovascular Test Request Form (T724) with the specimen.

Secondary ID

86202

Useful For

Aiding in the prognosis for patients diagnosed with heart failure

 

Risk stratification of patients with heart failure

 

An early indication of treatment failure and as a therapeutic target

Method Name

Enzyme-Linked Immunosorbent Assay (ELISA)

Reporting Name

Galectin-3, S

Specimen Type

Serum Red

Specimen Minimum Volume

0.2 mL

Specimen Stability Information

Specimen Type Temperature Time
Serum Red Frozen (preferred) 365 days
  Refrigerated  24 hours

Clinical Information

Heart failure is a complex cardiovascular disorder with a variety of etiologies and heterogeneity with respect to the clinical presentation of the patient. Heart failure is significantly increasing in prevalence with an aging population and is associated with high short- and long-term mortality rate. Over 80% of patients diagnosed and treated for acute heart failure syndromes in the emergency department are re-admitted within the forthcoming year, incurring costly treatments and therapies.

 

The development and progression of heart failure is a clinically silent process until manifestation of the disorder, which typically occurs late and irreversibly into its progression. Mechanistically, heart failure, whether due to systolic or diastolic dysfunction, is thought to progress primarily through adverse cardiac remodeling and fibrosis in response to cardiac injury or stress. Galectin-3 is a biomarker that appears to be actively involved in both the inflammatory and some fibrotic pathways.

 

Galectin-3 is a carbohydrate-binding lectin whose expression is associated with inflammatory cells, including macrophages, neutrophils, and mast cells. Galectin-3 has been linked to cardiovascular physiological processes including myofibroblast proliferation, tissue repair, and cardiac remodeling in the setting of heart failure. Concentrations of galectin-3 have been used to predict adverse remodeling after a variety of cardiac insults.

Reference Values

<24 months: Not established

2-17 years: ≤25.0 ng/mL

≥18 years: ≤22.1 ng/mL

Cautions

Galectin-3 has not been shown to be useful in the acute diagnosis of heart failure, and natriuretic peptides (BNP or NT-proBNP) should be utilized for this purpose.

 

Hemolysis has been shown to interfere with the galectin-3 assay due to intracellular release of galectin-3. Specimens that are visibly hemolyzed will be rejected.

 

Heterophile antibodies, in particular human-antimouse antibodies in human serum, may cause falsely elevated galectin-3 results. Heterophile antibodies may react with reagent immunoglobulins and subsequently interfere with in vitro immunoassays. Patients routinely exposed to animals or to animal serum products can be prone to this interference and anomalous high or low values can be observed.

 

Patients with high concentrations of rheumatoid factor, as well as other autoimmune disorders, may also yield falsely elevated results and should be interpreted with caution.

Day(s) Performed

Monday

Report Available

1 to 8 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

82777

NY State Approved

Yes