Test ID GRAB Giardia Antibody, IFA
Method Name
Immunofluorescence Assay (IFA)
Reporting Name
Giardia lamblia Ab, IFASpecimen Type
SerumDraw blood in a plain, red-top tube(s). Spin down and send 1 mL of serum refrigerated.
Note: Serum gel tube is acceptable, but must pour off into a plastic vial.
Specimen Minimum Volume
0.075 mL
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Serum | Refrigerated (preferred) | 14 days |
Frozen | 30 days | |
Ambient | 5 days |
Reference Values
REFERENCE RANGE: <1:16
INTERPRETIVE CRITERIA:
<1:16 Antibody Not Detected
1:16 Equivocal; submission of a second specimen (collected 3-4 weeks after initial specimen) suggested if clinically warranted
≥ 1:32 Antibody Detected
A polyvalent conjugate (recognizing IgG, IgM and IgA) is used to detect the presence of antibodies to Giardia lamblia. A four-fold or greater increase in titer between acute and convalescent sera indicates an acute active phase. A single positive reaction represents previous exposure, since antibody titers are known to remain high for at least six months.
Day(s) Performed
Monday through Saturday
Report Available
1 - 3 daysPerforming Laboratory
Focus Diagnositics, Inc.Test Classification
This assay was developed and its performance characteristics have been determined by Focus Diagnostics. It has not been cleared or approved by the U.S. Food and Drug Administration. The FDA has determined that such clearance or approval is not necessary. Performance characteristics refer to the analytical performance of the test.CPT Code Information
86674