Test ID LCADP Adenovirus, Molecular Detection, PCR, Plasma
Specimen Required
Collection Container/Tube: Lavender top (EDTA)
Submission Container/Tube: Screw-capped, sterile container
Specimen Volume: 1 mL
Collection Instructions: Centrifuge and aliquot plasma into a sterile, plastic vial.
Forms
If not ordering electronically, complete, print, and send a Microbiology Test Request (T244) with the specimen.
Useful For
Aiding in diagnosing adenovirus infections using plasma specimens
Method Name
Real-Time Polymerase Chain Reaction (PCR)/DNA Probe Hybridization
Reporting Name
Adenovirus PCR, PSpecimen Type
Plasma EDTASpecimen Minimum Volume
0.3 mL
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Plasma EDTA | Refrigerated (preferred) | 7 days |
| Frozen | 7 days |
Reference Values
Negative
Day(s) Performed
Monday, Wednesday, Friday
Report Available
2 to 5 daysPerforming Laboratory
Mayo Clinic Laboratories in Rochester
Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.LOINC Code Information
| Test ID | Test Order Name | Order LOINC Value |
|---|---|---|
| LCADP | Adenovirus PCR, P | 21055-9 |
| Result ID | Test Result Name | Result LOINC Value |
|---|---|---|
| 56088 | Adenovirus PCR, P | 21055-9 |
CPT Code Information
87798