Test ID LEGRP Legionella species, Molecular Detection, PCR
Useful For
Sensitive and rapid diagnosis of pneumonia caused by Legionella species
Method Name
Rapid Polymerase Chain Reaction (PCR)
(PCR is utilized pursuant to a license agreement with Roche Molecular Systems, Inc.)
Reporting Name
Legionella PCRSpecimen Type
VariesThe high sensitivity of amplification by PCR requires the specimen to be processed in an environment in which contamination of the specimen by Legionella DNA is unlikely.
Forms: If not ordering electronically, complete, print, and send 1 of the following forms with the specimen:
Microbiology Test Request Form (T244) (http://www.mayomedicallaboratories.com/it-mmfiles/microbiology_test_request_form.pdf)
Neurology Test Request Form (T732) (http://www.mayomedicallaboratories.com/it-mmfiles/neurology-request-form.pdf)
Specimen source is required.
Specimen Type: Respiratory
Sources: Sputum, tracheal secretions/aspirates, transtracheal aspirate, bronchial washing/aspirate, bronchoalveolar lavage, lung fluid or pleural fluid
Container/Tube: Sterile container
Specimen Volume: 1 mL
Specimen Type: Fresh tissue or biopsy
Sources: Lung tissue
Container/Tube: Sterile container
Specimen Volume: Entire collection
Specimen Minimum Volume
Fluid: 0.5 mL/Tissue: 5 mm(3)
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Varies | Refrigerated (preferred) | 7 days |
Frozen | 7 days |
Clinical Information
Legionnaires disease was first recognized during a pneumonia outbreak at the Legionnaires convention in Philadelphia in 1976. Investigators with the CDC isolated a novel, gram-negative bacillus, later named Legionella pneumophila. It is now widely recognized that Legionella pneumophila (and other members of the genus Legionella) cause Legionnaires disease.
Reference Values
Not applicable
Cautions
This assay does not differentiate between the Legionella species. The assay is not recommended as a test of cure because nucleic acid may persist after successful treatment. False-positive results are theoretically possible if patient specimens are contaminated with Legionella DNA, which may occur since Legionella species are environmental organisms present in aquatic environments. The following uncommonly encountered species of Legionella are not detected by this assay: Legionella anisa, Legionella feeleii, Legionella maceachernii, Legionella parisiensis, and Legionella sainthelensi.
Day(s) Performed
Monday through Sunday
Report Available
3 daysPerforming Laboratory

Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the U.S. Food and Drug Administration.CPT Code Information
87801