Sign in →

Test ID LIDO Lidocaine, Serum

Useful For

Assessing optimal dosing during the acute management of ventricular arrhythmias following myocardial infarction or during cardiac manipulation such as surgery

 

Assessing potential toxicity

Method Name

Immunoassay

Reporting Name

Lidocaine, S

Specimen Type

Serum Red

Container/Tube: Red top

Specimen Volume: 0.5 mL

Collection Instructions: Red-top tubes should be centrifuged and aliquoted within 2 hours of collection.

Specimen Minimum Volume

0.25 mL

Specimen Stability Information

Specimen Type Temperature Time
Serum Red Refrigerated (preferred) 14 days
  Ambient  14 days
  Frozen  14 days

Clinical Information

Lidocaine is commonly used as a local anesthetic, but is also effective at controlling ventricular arrhythmia and ventricular fibrillation in children and adults. For cardiac therapy, optimal therapeutic response is seen when serum concentrations are between 1.5 and 5.0 mcg/mL. Lidocaine is 50% protein-bound, primarily to alpha-1-acid glycoprotein; concentrations of this protein increase after myocardial infarction, which may decrease the amount of free lidocaine and thus its efficacy.

 

Lidocaine undergoes extensive first-pass hepatic metabolism and, thus, is not administered orally. It is eliminated via renal clearance, with a half-life of approximately 1.5 hours. Diseases that reduce hepatic or renal function reduce clearance and prolong elimination of lidocaine.

 

Toxicity occurs when the concentration of lidocaine is >6.0 mcg/mL and is usually associated with symptoms of central nervous system excitation, light-headedness, confusion, dizziness, tinnitus, and blurred or double vision. This can be accompanied by bradycardia and hypotension leading to cardiovascular collapse.

Reference Values

Therapeutic: 1.5-5.0 mcg/mL

Critical value: >6.0 mcg/mL

Cautions

No significant cautionary statements

Day(s) Performed

Monday through Sunday; Continuously

Report Available

Same day/1 day

Performing Laboratory

Mayo Medical Laboratories in Rochester

Test Classification

This test has been cleared or approved by the U.S. Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

80176

NY State Approved

Yes