Test ID OXYSU Oxycodone Screen, Urine
Useful For
Detection of oxycodone and oxymorphone in urine
Reflex Tests
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
OXYCU | Oxycodone w/metabolite Conf, U | Yes | No |
Testing Algorithm
Testing begins with screening assay. If oxycodone screen is positive, then the liquid chromatography-tandem mass spectrometry confirmation with quantification will be performed at an additional charge.
Method Name
Immunoassay
Reporting Name
Oxycodone Screen, USpecimen Type
UrineCollection Container/Tube: Plastic urine container
Submission Container/Tube: Plastic, 60-mL urine bottle
Specimen Volume: 20 mL
Collection Instructions:
1. Collect a random urine specimen.
2. Submit 20 mL in 1 plastic bottle.
3. No preservative.
Additional Information:
1. For situations where chain of custody is required, a Chain-of-Custody Kit (T282) is available. For chain-of-custody testing, order OXYSX / Oxycodone Screen, Chain of Custody, Urine.
2. If urine creatinine is required or adulteration of the sample is suspected, the following test should be requested, ADULT / Adulterants Survey, Urine. For additional information, please refer to ADULT / Adulterants Survey, Urine.
Forms: Chain-of-Custody Request Form is included in the Chain-of-Custody Kit (T282). A copy of this form is also available at http://www.mayomedicallaboratories.com/it-mmfiles/chain-of-custody-request-form.pdf.
Specimen Minimum Volume
2.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Urine | Refrigerated (preferred) | 14 days |
Frozen | 14 days | |
Ambient | 72 hours |
Clinical Information
Opiates are the natural or synthetic drugs that have a morphine-like pharmacological action. Medically, opiates are used primarily for relief of pain. Opiates include morphine and drugs structurally similar to morphine (eg, codeine, hydrocodone, hydromorphone, oxycodone, oxymorphone).
Oxycodone is metabolized to noroxycodone, oxymorphone and their glucuronides and is excreted primarily via the kidney. The presence of oxycodone greater than 100 ng/mL indicates exposure to oxycodone within 2 to 3 days prior to specimen collection.
Oxymorphone is metabolized in the liver and excreted via the kidney primarily as the glucuronide conjugates. Oxymorphone is also a metabolite of oxycodone and therefore the presence of oxymorphone could also indicate exposure to oxycodone.
Reference Values
Negative
Screening cutoff concentration:
Oxycodone: 100 ng/mL
Cautions
Other drugs in the opioid class, such as fentanyl, meperidine, methadone, and opiate antagonists such as naloxone, are not detected.
Day(s) Performed
Monday through Friday
Report Available
Same day/1 dayPerforming Laboratory

Test Classification
This test has been cleared or approved by the U.S. Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
80301
G0479 (if appropriate)