Test ID RIBAV Ribavirin, Serum

Useful For

Assessing adequacy of ribavirin therapy or potential drug-related toxicity

Method Name

Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS)

Reporting Name

Ribavirin, S

Specimen Type

Serum

Collection Container/Tube:

Preferred: Red top

Acceptable: Serum gel

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL

Collection Instructions: Spin down and separate serum from cells within 2 hours of draw. Delay will result in falsely-decreased ribavirin concentrations.

Specimen Minimum Volume

0.2 mL

Specimen Stability Information

Specimen Type Temperature Time
Serum Frozen (preferred) 14 days
  Refrigerated  14 days
  Ambient  24 hours

Clinical Information

Ribavirin is a nucleoside analog with antiviral activity against a number of RNA and DNA viruses, including hepatitis C virus (HCV). In combination with interferon, ribavirin is a treatment of choice for chronic HCV infection. In this setting, higher serum concentrations of ribavirin appear to correlate with the likelihood of achieving virological response; however, the drug dose is limited by concentration-dependent hemolytic anemia. Although no consensus therapeutic targets or toxic thresholds have been established, ribavirin concentrations between 2,500 and 4,000 ng/mL have been suggested to improve virological response and minimize toxicity.

 

The half-life of ribavirin is very long, typically 5 days or more. For this reason, steady-state concentrations are not achieved until several weeks into therapy; most studies have performed initial therapeutic monitoring after at least 28 days of ribavirin treatment. Specimens should be drawn immediately prior to the next scheduled dose, or at minimum >12 hours after the last dose.

 

Elimination of ribavirin is also very slow, and due to incorporation of the drug into red blood cells, may take up to 6 months after the cessation of therapy. Ribavirin has shown teratogenic activity in animal models, thus patients are recommended to practice stringent birth control until at least 6 months after the end of treatment.

Reference Values

2,500-4,000 ng/mL

Cautions

Therapeutic targets have not been well established; reference values are provided as a guide to interpretation but are not definitive.

 

Serum must be removed from cells within 2 hours. Delayed processing can result in decreased ribavirin concentration.

Day(s) Performed

Tuesday; 4 p.m.

Report Available

2 days

Performing Laboratory

Mayo Medical Laboratories in Rochester

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the U.S. Food and Drug Administration.

CPT Code Information

80299

NY State Approved