Test ID SGSS Synthetic Glucocorticoid Screen, Serum


Ordering Guidance


This method cannot detect the presence of fluticasone propionate in serum. Fluticasone propionate is quickly metabolized to fluticasone 17-beta carboxylic acid in urine. To screen for this metabolite, order 17BFP / Fluticasone 17-Beta-Carboxylic Acid, Random, Urine.



Specimen Required


Collection Container/Tube:

Preferred: Red top

Acceptable: Serum gel

Submission Container/Tube: Plastic vial

Specimen Volume: 2 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Useful For

Confirming the presence of listed synthetic glucocorticoids (see Interpretation)

 

Confirming the cause of secondary adrenal insufficiency

 

This test is not useful for detection of fluticasone propionate.

Method Name

Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS) Stable Isotope Dilution Analysis

Reporting Name

Synthetic Glucocorticoid Screen, S

Specimen Type

Serum

Specimen Minimum Volume

1.1 mL

Specimen Stability Information

Specimen Type Temperature Time
Serum Frozen (preferred) 14 days
  Refrigerated  7 days
  Ambient  24 hours

Clinical Information

Synthetic glucocorticoids are widely used and have important clinical utility both as anti-inflammatory and immunosuppressive agents. The medical use of these agents, as well as their surreptitious use, can sometimes lead to a confusing clinical presentation. Patients exposed to these steroids may present with clinical features of Cushing syndrome but with suppressed cortisol levels and evidence of hypothalamus-pituitary-adrenal axis suppression.

Reference Values

Negative

Cutoff concentrations

Betamethasone: 0.10 mcg/dL

Budesonide: 0.20 mcg/dL

Dexamethasone: 0.10 mcg/dL

Fludrocortisone: 0.10 mcg/dL

Megestrol acetate: 0.10 mcg/dL

Methylprednisolone: 0.10 mcg/dL

Prednisolone: 0.10 mcg/dL

Prednisone: 0.10 mcg/dL

Triamcinolone acetonide: 0.10 mcg/dL

 

Values for normal patients not taking these synthetic glucocorticoids should be less than the cutoff concentration (detection limit).

Cautions

This method cannot detect all available synthetic steroids available either as pharmaceutical compounds or chemicals present in food. The assay confirms only the listed synthetic glucocorticoids. For more information see Interpretation.

 

Lack of detection does not preclude use of synthetic glucocorticoids because adrenal suppression may persist for some time after the exogenous steroid is discontinued.

Day(s) Performed

Wednesday

Report Available

5 to 9 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

80299

NY State Approved

Yes