Sign in →

Test ID TRSF Transferrin, Serum

Useful For

Screening for chronic iron overload diseases, particularly hereditary hemochromatosis

Method Name

Immunoturbidimetric Assay

Reporting Name

Transferrin, S

Specimen Type

Serum

Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Specimen Volume: 0.6 mL

Collection Instructions:

1. Serum gel tubes should be centrifuged within 2 hours of collection.

2. Red-top tubes should be centrifuged and aliquoted within 2 hours of collection.

Forms: If not ordering electronically, complete, print, and send a Benign Hematology Test Request Form (T755) with the specimen (http://www.mayomedicallaboratories.com/it-mmfiles/benign-hematology-test-request-form.pdf)

Specimen Minimum Volume

0.25 mL

Specimen Stability Information

Specimen Type Temperature Time
Serum Refrigerated (preferred) 7 days
  Frozen  180 days
  Ambient  7 days

Clinical Information

Transferrin is a glycoprotein with a molecular weight of 79570 daltons. It consists of a polypeptide strand with 2 N-glycosidically linked oligosaccharide chains and exists in numerous isoforms. The rate of synthesis in the liver can be altered in accordance with the body’s iron requirements and iron reserves. Transferrin is the iron transport protein in serum. In cases of iron deficiency, the degree of transferrin saturation appears to be an extremely sensitive indicator of functional iron depletion. The ferritin levels are depressed when there is a deficiency of storage iron. In sideropenia, an iron deficiency can be excluded if the serum transferrin concentration is low, as in inflammation or less commonly, in cases of ascorbic acid deficiency. In screening for hereditary hemochromatosis, transferrin saturation provides a better indication of the homozygous genotype than does ferritin. The treatment of anemia with erythropoietin in patients with renal failure is only effective when sufficient depot iron is present. The best monitoring procedure is to determine transferrin saturation during therapy. Transferrin saturation in conjunction with ferritin gives a conclusive prediction of the exclusion of iron overloading in patients with chronic liver disease.

Reference Values

200-360 mg/dL

Cautions

Measurement of serum iron, iron binding capacity, and percent saturation should not be used as the primary test for iron deficiency. It may be helpful in conjunction with ferritin and soluble transferrin receptor, especially in patients with inflammation.

Day(s) Performed

Monday through Saturday; Continuously

Report Available

Same day/1 day

Performing Laboratory

Mayo Medical Laboratories in Rochester

Test Classification

This test has been cleared or approved by the U.S. Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

84466

NY State Approved

Yes